Product Details
Product Details
Summary
- Ultra High Efficiency Quint Zone (5 Circuit) Outdoor Condensing System
- Cooling Capacity: 42,000 BTU with 22.0 SEER2 / 11.2 EER2 efficiency
- Heating Capacity: 42,000 BTU with 10.0 HSP2 / 3.5 COP2 efficiency
- Energy-Star Cold-Climate Designated Performance
- Wide Ambient Operation Range (As low as -13°F in Heating / As high as 131°F in Cooling)
-
Factory Precharged to Cover Up to 125 Ft. of Total Combined Attached Lineset Length
- Can be Utilized as a Stronger Quad or Triple or Dual-Zone System by Leaving 3rd and/or 4th and/or 5th Zones Closed
Specifications
- Part Number: YN050GLSI24M5G
- Power Supply: 208~230V, 60Hz, 1Ph
- Communication Protocol: Current Loop
- Min-Max Load Attached: 18,000~63,000 BTU/h
-
Refrigerant Type: R454B
- Minimum Room Size: 135 sq ft
- Maximum Circuit Breaker: 45A (double-pole)
- Net Dimensions (WDH): 42"-1/4 x 18"-3/8 x 33"-1/2 Inches
- Carton Dimensions (WDH): 44"-5/8 x 20"-7/8 x 38"-1/8 Inches
- Net / Gross Weight: 174.2 / 198.4 lbs
- AHRI Reference: 217048771 (Ductless) / 217048775 (Ducted)
Performance
- Cooling Rated Capacity (Ductless): 42,000 BTU/h
- Cooling Rated Capacity (Ducted): 41,000 BTU/h
- Cooling Capacity Range (Ductless/Ducted): 6,500~46,000 BTU/h
- Cooling SEER2 (Ductless): 22.0 BTU/W.h
- Cooling SEER2 (Ducted): 20.0 BTU/W.h
- Cooling EER2 (Ductless): 11.2 BTU/W.h
- Cooling EER2 (Ducted): 11.7 BTU/W.h
- Heating Rated Capacity (Ductless): 42,000 BTU/h
- Heating Rated Capacity (Ducted): 42,000 BTU/h
- Heating Capacity Range (Ductless/Ducted): 6,500~46,000 BTU/h
- Heating HSPF2 Region IV/V (Ductless): 10.0 / 7.8 BTU/W.h
- Heating HSPF2 Region IV/V (Ducted): 8.5 / 7.3 BTU/W.h
- Heating C.O.P.2 47°F/5°F (Ductless): 3.5 / 2.0 W/W
- Heating C.O.P.2 47°F/5°F (Ducted): 3.2 / 1.9 W/W
- Sound Level: 65 dB(A)
Technical Information & Certifications
- AHRI Certificate (Ductless Indoor Units / Ducted Indoor Units)
- Energy Guide
Submittal Sheets
- High Wall
Submittal Sheet - Ceiling Cassette
Submittal Sheet - Flex Mount
Submittal Sheet - Ceiling Concealed
Submittal Sheet
Quint Zone Combinations (in thousands BTU)
| Two Units | Three Units | Four Units | Five Units |
|---|---|---|---|
| 9 + 9 | 9 + 9 + 9 | 9 + 9 + 9 + 9 | 9 + 9 + 9 + 9 + 9 |
| 12 + 9 | 12 + 9 + 9 | 12 + 9 + 9 + 9 | 12 + 9 + 9 + 9 + 9 |
| 18 + 9 | 18 + 9 + 9 | 18 + 9 + 9 + 9 | 18 + 9 + 9 + 9 + 9 |
| 24 + 9 | 12 + 12 + 9 | 12 + 12 + 9 + 9 | 24 + 9 + 9 + 9 + 9 |
| 12 + 12 | 18 + 12 + 9 | 18 + 12 + 9 + 9 | 12 + 12 + 9 + 9 + 9 |
| 18 + 12 | 24 + 12 + 9 | 12 + 12 + 12 + 9 | 18 + 12 + 9 + 9 + 9 |
| 24 + 12 | 18 + 18 + 9 | 18 + 12 + 12 + 9 | 24 + 12 + 9 + 9 + 9 |
| 18 + 18 | 24 + 18 + 9 | 24 + 12 + 12 + 9 | 18 + 18 + 9 + 9 + 9 |
| 24 + 18 | 24 + 24 + 9 | 24 + 18 + 12 + 9 | 12 + 12 + 12 + 9 + 9 |
| 24 + 24 | 12 + 12 + 12 | 12 + 12 + 12 + 12 | 18 + 12 + 12 + 9 + 9 |
| 18 + 12 + 12 | 18 + 12 + 12 + 12 | 12 + 12 + 12 + 12 + 9 | |
|
|
24 + 12 + 12 | 24 + 12 + 12 + 12 | 18 + 12 + 12 + 12 + 9 |
| 18 + 18 + 12 | 18 + 18 + 12 + 12 | 12 + 12 + 12 + 12 + 12 | |
| 24 + 18 + 12 |
|
||
| 24 + 24 + 12 |
|
||
| 18 + 18 + 18 |
|
||
| 24 + 18 + 18 | |||
|
|
9,000 BTU Compatible Units
- Wall Mounted: WT009GLSI24HLG (32"-1/4 x 7"-5/8 x 12" Inches WDH)
- Ceiling Cassette: CT009GLSILCFHG (22"-1/2 x 22"-1/2 x 9"-5/8 Inches WDH)
- Ductable Concealed: RT009GLSILCFHG (27"-1/2 x 19"-1/4 x 7"-7/8 Inches WDH)
12,000 BTU Compatible Units
- Wall Mounted: WT012GLSI24HLG (36"-1/2 x 7"-5/8 x 12" Inches WDH)
- Ceiling Cassette: CT012GLSILCFHG (22"-1/2 x 22"-1/2 x 9"-5/8 Inches WDH)
- Ductable Concealed: RT012GLSILCFHG (27"-1/2 x 19"-1/4 x 7"-7/8 Inches WDH)
18,000 BTU Compatible Units
- Wall Mounted: WT018GLSI24HLG (43"-1/8 x 8"-3/4 x 13" Inches WDH)
- Ceiling Cassette: CT018GLSILCFHG (22"-1/2 x 22"-1/2 x 9"-5/8 Inches WDH)
- Ductable Concealed: RT018GLSILCFHG (35"-1/2 x 19"-1/4 x 7"-7/8 Inches WDH)
- Floor-Ceiling Flex Console: UT018GLSILCFHG (41"-1/2 x 26"-1/2 x 9"-1/4 Inches WDH)
24,000 BTU Compatible Units
- Wall Mounted: WT024GLSI24HLG (43"-1/8 x 8"-3/4 x 13"-1/8 Inches WDH)
- Ceiling Cassette: CT024GLSILCFHG (33"-1/8 x 33"-3/4 x 10"-3/4 Inches WDH)
- Ductable Concealed: RT024GLSILCFHG (43"-1/4 x 17"-3/4 x 7"-7/8 Inches WDH)
- Floor-Ceiling Flex Console: UT024GLSILCFHG (41"-1/2 x 26"-1/2 x 9"-1/4 Inches WDH)
Min. / Max. Loading
18,000 / 63,000 BTU/h.
Series Details
Series Details
Multi-Zone Quantum Ultra™ Mini Split Outdoor Units
- Choosing a selection results in a full page refresh.
- Opens in a new window.
placeholder