Pioneer® Triple (3) Zone Quantum Series Outdoor Section 23.5 SEER2 Multi Split Inverter++ Energy-Star Air Conditioner & Heat Pump 230V

SKU: YN030GMFI22M3E

Price:
Sale price$1,628.00 Regular price$1,990.00

Shipping calculated at checkout

Financing:
Stock:
In stock

THIS IS AN OUTDOOR SECTION ONLY, YOU NEED TO ALSO PURCHASE A COMPATIBLE INDOOR SECTION IN ORDER TO HAVE A COMPLETE WORKING SYSTEM.

Pickup available at PD Doral

Usually ready in 24 hours

Description

R410A Pre-Charged Outdoor Unit, accommodating refrigerant line lengths up to 25 ft. per circuit

Performance

  • Power Supply: 208~230V, 60Hz, 1Ph
  • Communication Protocol: Current Loop
  • Min-Max Load Attached: 18,000~36,000 BTU/h
  • Cooling Rated Capacity: 27,000 BTU/h
  • Cooling Capacity Range: 8,500~32,000 BTU/h
  • Cooling SEER2 (Ductless): 23.5 BTU/W.h
  • Cooling EER2 (Ductless): 12.2 BTU/W.h
  • Heating Rated Capacity: 28,000 BTU/h
  • Heating Capacity Range: 3,690~32,860 BTU/h
  • Heating HSPF2 (Ductless): 9.2 BTU/W.h
  • Refrigerant Type: R410a
  • Suitable Area: 800~1,200 Sq.F
  • Sound Level: 60.0 dB(A)
  • Net Dimensions (WDH): 37.2 x 16.2 x 31.8 Inches
  • Carton Dimensions (WDH): 42.8 x 19.6 x 34.8 Inches
  • Net / Gross Weight: 140 / 151 Lbs

Manuals & Documents

Triple Zone Combinations (in thousands BTU)

Rating Two Units Three units    
Wall: 9 + 9 + 9 9 + 9 9 + 9 + 9    
Ducted: 9 + 9 + 9 9 + 12 9 + 9 + 12    
  9 + 18 9 + 9 + 18    
  12 + 12 9 + 12 + 12    
  12 + 18 12 + 12 + 12    
  18 + 18
   

9,000 BTU Compatible Units

12,000 BTU Compatible Units

18,000 BTU Compatible Units

Min. / Max. Loading

18,000 / 36,000 BTU/h.

Notes

Every indoor unit attached will operate at a random, self regulated capacity, based on the actual demand it measures from the zone it is serving (Between 30% to 100% of its rated capacity or OFF). Outdoor unit will also self regulate its output capacity, based on the total demand it reads from all of the simultaneously running indoor units at any given moment.

With multi split systems, the total demand from the outdoor unit, shall seldomly exceed 67% of the total available capacity of the combined indoor unit group due to load fluctuations. Although very seldom, if and when the total demand from the combined indoor group exceeds the rated capacity of the outdoor unit, the capacity of the each indoor unit will be annotated accordingly.

For high demand heating applications, max loading limits may need to be reduced by 10-15 % to avoid under-performance risks at some extreme conditions.